Details
Features
- Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
- Scalable runtime
Allows additional run time to be quickly added as needed.
- Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
- Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Manageability
- Network manageable
Provides remote management of the UPS over the network.
- InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
- SmartSlot
Customize UPS capabilities with management cards.
- LED status indicators
Quickly understand unit and power status with visual indicators.
- Serial Connectivity
Provides management of the UPS via a serial port.
Adaptability
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.
Serviceability
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
- Disconnected battery notification
Warns when a battery is not available to provide backup power.
- Audible alarms
Provides notification of changing utility power and UPS conditions
Protection
- Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
- Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
- Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
- Cold-start capable
Provides temporary battery power when the utility power is out.
- Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
- Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Additional
Brand | APC |
---|